Axis Pts Tab
Axis Pts define axes that are shared across multiple Characteristic curves or maps. These axes have a Characteristic Axis Type = COM_AXIS.
The Axis Pts tab has a table to display all A2L file Axis Pt items and their properties. Each row (below the 1st filtering row) defines an Axis and each column is a property. The default column configuration is shown in Figure 1.
Columns in the table can be filtered, reorganized, added, and hidden. These table features are common across all tabs in this area.
To add items to the table you can:
- Drag/drop symbols from an ECU map file.
- Use the Create tool or right click menu selection.
- Import an existing A2L file.
To edit items already in the table with the Edit Axis Pts dialog you can:
- Double click on a cell in the table.
- Use the Edit tool or right click menu selection.
Refer to Table 1 below for a description of each column on the Axis Pts tab.
Table 1: Column Descriptions for the Axis Pts Tab
Default Columns | Description |
---|---|
Name | Unique identifier of the Axis Pts. Here are the main requirements for this field:
If in doubt about valid names, please refer to the ASAM specifications. |
InputQuantity | References a Measurement to be used as a working point on the axis to track along the curve or map. The dropdown selections come from the Measurements tab. |
Address | Memory Address of the Axis Pts in the ECU. |
Deposit | Specifies the data structure. The default layout will update depending upon the Data Type field. The dropdown selections come from the Record Layouts tab. The Data Type over on the Record Layout tab must match the Data Type field on this dialog. |
Conversion | Applies the selected Conversion Method to the value. The dropdown selections come from the Conversion Methods tab. |
MaxAxisPoints | Maximum number of axis points. |
LowerLimit | Lower limit of plausible range of values. A default limit is determined mathematically by the Data Type selection. Note: The default limit is reapplied each time the Data Type is changed. |
UpperLimit | Upper limit of plausible range of values. A default limit is determined mathematically by the Data Type selection. Note: The default limit is reapplied each time the Data Type is changed. |
MaxDiff | Maximum adjustment allowed to an axis point. Entered as an absolute value, not as a percentage. |
Format | Display formatting applied to numerical values. If specified, this Format property overrides any formatting in the Conversion Method property. The syntax for this field is: %Length.Layout
|
Hidden Columns | Description |
---|---|
CalibrationAccess | There are 4 types of access for MCD systems or test tools:
|
DataType | Determines the number of bytes dedicated to the value and how those bytes are interpreted. This property should be chosen early because it applies defaults to the Lower/Upper Limit and Extended Lower/Upper Limit properties.
|
DisplayIdentifier | An alternative display name that is usually much shorter than the Name property. Can be useful for devices with small display areas. |
ExtendedLowerLimit | Extends the lower limit of plausible values. Can be useful for generating warnings when the Lower Limit is exceeded. A default limit is determined mathematically by the Data Type selection. Note: The default limit is reapplied each time the Data Type is changed. |
ExtendedUpperLimit | Extends the upper limit of plausible values. Can be useful for generating warnings when the Upper Limit is exceeded. A default limit is determined mathematically by the Data Type selection. Note: The default limit is reapplied each time the Data Type is changed. |
KeyName | Name from a map file symbol dropped into the A2L item area. |
LongIdentifier | Comment or description. |
Manual Flag | Manual flag setting from the Address tab on the Axis Pts' edit dialog. |